Service
GE gas dryer igniter and valve repair
A gas dryer that tumbles without heat is usually the igniter, the flame sensor or the valve coils, and the three fail in a sequence that is diagnosable by watching one cycle: whether the igniter glows, how long it glows, and whether the flame lights and then goes out.
- From $95 diagnostic, credited to the repair
- 59 cities and neighborhoods covered
- OEM parts available on order
- In writing the price, before anything is opened
Before you read on
What this job costs and how it is agreed
A starting figure, not a quote. What moves it is the model, how the unit is built in and which part it needs — settled after the on-site diagnostic.
Starts at
from $195
After a diagnostic from $95, which comes off the bill when you go ahead.
or call (305) 306-2503
Diagnostic
From $95, credited to the repair
The price
In writing, before anything is opened
Warranty
On the labor we performed
On the visit
How this visit actually goes
The same order every time, so nothing is opened and nothing is charged before you have seen the figure and said yes.
-
01
Watch the ignition sequence
Glow, light, sustain. Where it stops is the diagnosis, and it takes one cycle.
-
02
Test the flame sensor and the coils
A sensor that has drifted will not call for gas; coils that have weakened will not hold the valve open.
-
03
Check the vent, again
Because a gas dryer with restricted airflow trips its protection exactly like an electric one, and the symptom is identical.
-
04
Fit, test and check for leaks
With the gas on and the meter on the connection, before anything is closed up.
-
05
The leak test that ends every gas job
With the gas on and a meter on the connection, before anything is closed up. It is part of the figure rather than an option.
Applies to
The GE units we carry this work out on
-
Electric and gas · vented and condensation GE dryer repair in Miami
Electric and gas dryers, vented and condensation. The single most common call — it runs but the clothes are still wet — is usually not the dryer: it is the vent. In this county that duct runs through humid air and often through a long horizontal path, and a restricted one costs drying time, electricity and eventually the heating element it overheats.
- Takes too long to dry is usually the vent
- A restricted vent is a safety issue, not just a slow one
- GE publishes no error codes for basic dryers
In more detail
About GE gas dryer igniter and valve repair
Diagnosed by watching one ignition cycle
A gas dryer that is not heating tells you everything in about ninety seconds if somebody watches the burner through a cycle: whether the igniter glows, whether the valve opens, whether the flame catches and then goes out. Igniter, flame sensor and valve coils fail in roughly that order of likelihood, and the order changes with what the cycle shows. This is gas work, it is done to code, and the parts of it that are not a home repair are said plainly rather than implied.
This article is based on:
- Official manufacturer documentation
- Internal repair procedures
- Technician repair history
- Company quality standards
Before you book
Questions about GE gas dryer igniter and valve repair
The drum turns and the clothes stay wet.
On a gas dryer that is ignition or venting. Watching one cycle at the burner separates them, and it is the first thing we do.
Is this safe to look at myself?
Looking is fine. Working on the gas valve or the supply is not, and we would rather you called somebody than found out.
Where we do it
Across Miami-Dade, Broward, and Palm Beach
Same terms everywhere we go: an on-site diagnostic first, the price agreed in writing, and the exact figure confirmed once we have seen the unit.